Classified by application |
|
|
|
|
|
|
KLD20S 2-way motorized ball valve (1/4" to 1") |
|


|
Features:
1.Mini Dimension suits for small equipment
2.Patented technology--floating seal structure
3.Long service life — 70,000- 100,000 circles
4.Low working current, suitable for battery driving
5.Manual override is safe and convenient
6.IP67 Enclosure
|
|
|
|
1.HVAC
2.Water treatment
3.Chemical process
4.Small equipment for automatic control
5.Replacing solenoid valve, particularly when solenoid cannot work reliably |
|
|
Dimension

Technical Parameters
Series |
Max
Torque |
Operating
Time |
Working
Voltage |
Max
Power |
Enclosure |
Max
Pressure |
Medium
Temperature |
Ambient
Temperature |
Humidity |
KLD20S |
2N.m |
about5S |
5V |
3W |
IP67 |
1.0Mpa |
0-100°C |
-20°C<
t<45°C |
≤85%
non-condensing |
12V,24V |
4W |
110V ,220V |
5W |
Full port ball valve connection size
DN |
D1/D2 |
d |
L1/L2 |
L3 |
H1 |
H2 |
F |
W(kg) |
DN8 |
G1/4" |
8 |
11 |
43 |
11 |
18.25 |
17 |
0.26 |
DN10 |
G3/8" |
10 |
11.5 |
50 |
12.5 |
19.75 |
20 |
0.31 |
DN15 |
G1/2" |
15 |
13 |
57 |
16.5 |
21.25 |
27 |
0.37 |
DN20 |
G3/4" |
20 |
16 |
70 |
21.5 |
25.75 |
32 |
0.52 |
Reduced port ball valve connection size
DN |
D1/D2 |
d |
L1/L2 |
L3 |
H1 |
H2 |
F |
W(kg) |
DN20 |
G3/4" |
15 |
15 |
64.5 |
16.5 |
21.25 |
30 |
0.37 |
DN25 |
G1" |
20 |
18 |
76 |
21.5 |
24.75 |
38 |
0.52 |
DN32 |
G1-1/4" |
20 |
20 |
80 |
24 |
24.75 |
48 |
0.70 |
Main components
Parts |
Material |
Actuator housing |
ABS |
Valve body |
Brass,304,316 |
Valve ball |
Brass,304,316 |
Stem |
Brass,304,316 |
Ball seat |
PTFE |
Seal |
EPDM |

Instructions for Manual override
1.It is only permitted to use when power is cut.
2.Lift the hand-wheel, and turn it left or right until the valve is in place.
3.When the black line on the indicator is horizontal, the valve is on; when vertical, the valve is off.
4.Press down hand-wheel after using manual override in order to work properly when power is supplied.
Wring: B2, B3, BD3 are available
1.The service life is the testing data in the condition of 1.0Mpa, 200L/h, tap water as working
medium. Different working occasions will influence the service life.
2.Manual shaft and hand-wheel will be replaced by rubber seal if manual override function is not needed.
3.Actuators are not direct-mount-on. Actuators are not recommended to be sold separately.
|
|
|